Combined stationary low-pressure testing equipment, model ND1+1

 

Product code: 450000

 

Combined stationary low-pressure testing equipment ND1 +1 model for testing of fire extinguishers and pressure vessels up to 30 bar max.

Scope of low pressure:

The testing of fire extinguishers containers and pressure vessels up to 30 bar .

- Max diameter 210mm

- Maximum permitted height of 730mm

- Two independent clamping position

- Features quick-release adapter. You must be the size of the pressure vessel equipped with adequately long discharge pipe.

- Adaptation of pressure vessels is performed using the quick test, while put pressure vessel head adapter.

- Clamping pressure vessels is performed pneumatically.

- Management of the process is provided by SPS.

- The test process is triggered manually by pressing start, the procedure of the test process is performed automatically using SPS.

- During pressurization test area is provided with sliding doors. Implementation of water in a pressure line directly into the pressure vessel. Water is pumped from the water tank pump directly into the pressure vessel.

- Pressurization is performed using one piston pump driven by compressed air (all parts in contact with water are made of stainless steel).

- Pressure measurement is performed by a pressure sensor and displayed on the digital display.

- Turn off preset pressure test is done automatically; Displays the current pressure on the display.

- Check the test pressure for racing set the stop time is automatically signal when the failed pressure test.

- The successful pressure test will automatically flush the pressure vessel with compressed air. Water is pumped directly into the water tank

- Pressure test is performed at each pressure vessel separately. Scope of low pressure tests 0-30 bar

- Pressure test or filling adapter for rapid testing is performed alternately.

- Compressed air-powered water pumping

- Interior lighting test equipment


Optional Accessories:

- Control unit for storing data using a PC

- Ability to enter data using the keyboard extinguisher.

- Determination of pressure and record the pressure is done by a software program and displayed on the screen.

Technical parameters:


Dimensions (D x W x H): approx 2200 x 2200 x 950mm (without control cabinets and control units)

Pneumatic connection: 1/2 ", 6-8 bar

Connecting the water inlet to the pressure-pumps: 1/2 "

Connections for emptying water: 1"

Electrical connection: 230 V, 50 Hz , 10 A

Filling pump: 230

Drive high-pressure pump: max 6-8 bar

Color: Blue hammered enamel or customer